The ASEA Trident system allows two 50A shore cords to be combined to a Single 100A output. The pair of DBT12s provide three levels of boost to keep your ship powered even when input voltages sag by 30%. The paralleling box ensures that current is shared equally between the shore cords, allowing you to maximize the amount of power you can draw from even the worst shore cord conditions. The three piece system is a direct replacement for the popular and discontinued Charles PM3.
If only one shore cord is available, the 50A source will be delivered to both outputs. When the second cord is attached, the sources will combine to form a Single 100A output. If one cord fails, the unit will automatically fall back to a Single source solution. The method used to combine sources allows for sharing power between shore cords WITHOUT the danger of tripping even the most sensitive GFI equipped pedestal.
Features
- Combining of shore cord inputs to create a Single output
- Auto-Restart from shore brownout, blackout, or overload
- Shore cord leveling keeps both cords at the same current to prevent imbalance and tripping
- Fault shield for bonded, galvanic bridged/isolated ground
- Modbus (RS-485) remote diagnostics
- Reverse Phase detection and correction
- Advanced power monitoring
- Microprocessor based over and under voltage / current protection
Direct Replacement
Intelligent Paralleling
GFI Compliant
SPECIFICATIONS
Model | Trident24 | Trident30* | |
Part Number |
628008 |
628013 |
|
Input Power Form |
Single |
Single |
Single |
Input Voltage |
240 V |
230 V |
240 V |
Input Frequency |
57-70 Hz
|
47-53 Hz |
57-70 Hz |
Input Current, Continuous |
2 x 50 A
|
2 x 63 A |
2 x 50 A |
Input Current, Overload |
2 x 100 A
|
2 x 125 A |
2 x 100 A |
Shore Cord Input |
Dual |
Dual |
Dual |
Output Power Rating |
24 kVA |
30 kVA |
24 kVA |
Auto Restart |
Standard |
Standard |
Standard |
Output Power Form |
Split |
Split |
Split |
Output Voltage |
120/240 V |
115/230 V |
115/230 V |
Output Frequency |
Same as input |
Same as input |
Same as input |
Output Current, Continuous |
100 A** |
125 A**h6> |
100 A** |
Output Current, Overload |
200 A** |
250 A**h6> |
200 A** |
Efficiency |
97% @ rated load |
97% @ rated load |
|
Cooling |
Air |
Air |
|
Mounting |
Floor |
Floor |
|
Series |
Trident |
Trident |
|
Weight |
58, 58, 19 kg / 127, 127, 42 lbs |
N/A |
|
Height |
30.6, 30.6, 30.7 cm / 12.0, 12.0, 12.1 in |
33.1, 33.1, 30.7 cm / 13.0, 13.0, 12.1 in |
|
Width |
33.4, 33.4, 33.5 cm / 13.1, 13.1, 13.2 in |
33.4, 33.4, 33.5 cm / 13.1, 13.1, 13.2 in |
|
Depth |
47.4, 47.4, 42.9 cm / 18.7, 18.7, 16.9 in |
49.4, 47.4, 42.9 cm / 19.4, 18.7, 16.9 in |
*under development
**if shore cord inputs are in phase